Nictiz FHIR NL STU3 Zib2017
1.3.15 - CI Build
Nictiz FHIR NL STU3 Zib2017 - Local Development build (v1.3.15) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Draft as of 2024-04-09 |
Mappings for the zib-VisualFunction-VisualAidProduct resource profile.
Zib VisualFunction VisualAid Product | ||
Device | ||
type | NL-CM:10.1.3 | ProductType |
Zib VisualFunction VisualAid Product | ||
Device | NL-CM:10.1.2 | Product |
identifier | NL-CM:10.1.4 | ProductID |
type | NL-CM:10.1.3 | ProductType |
note | ||
text | NL-CM:10.1.13 | ProductDescription |
Zib VisualFunction VisualAid Product | ||
Device | NL-CM:10.1.2 | Product |
identifier | NL-CM:10.1.4 | ProductID |
type | NL-CM:10.1.3 | ProductType |
note | ||
text | NL-CM:10.1.13 | ProductDescription |
Zib VisualFunction VisualAid Product | ||
Device | NL-CM:10.1.2 | Product |
identifier | NL-CM:10.1.4 | ProductID |
identifier (serialNumber) | NL-CM:10.1.4 | ProductID. serial number (21) part of the UDI |
udi | ||
deviceIdentifier | NL-CM:10.1.4 | ProductID. application identifier (AI) (01) part of the udi |
carrierHRF | NL-CM:10.1.4 | ProductID |
type | NL-CM:10.1.3 | ProductType |
lotNumber | NL-CM:10.1.4 | ProductID. batch or lot number (10) part of the UDI |
expirationDate | NL-CM:10.1.4 | ProductID. expiration date (17) part of the UDI |
note | ||
text | NL-CM:10.1.13 | ProductDescription |
Zib VisualFunction VisualAid Product | ||
Device | ||
type | ||
text | NL-CM:13.1.29 | SpecimenSource |
Zib VisualFunction VisualAid Product | ||
Device | ||
identifier | NL-CM:0.0.6 | IdentificationNumber |
patient | NL-CM:0.0.11 | Subject |
Zib VisualFunction VisualAid Product | ||
Device | Entity. Role, or Act, Device | |
text | Act.text? | |
contained | N/A | |
extension | N/A | |
modifierExtension | N/A | |
identifier | .id | |
identifier (serialNumber) | .id | |
id | n/a | |
extension | n/a | |
use | Role.code or implied by context | |
type | Role.code or implied by context | |
id | n/a | |
extension | n/a | |
coding | union(., ./translation) | |
id | n/a | |
extension | n/a | |
system | ./codeSystem | |
version | ./codeSystemVersion | |
code | ./code | |
display | CV.displayName | |
userSelected | CD.codingRationale | |
text | ./originalText[mediaType/code="text/plain"]/data | |
system | II.root or Role.id.root | |
value | II.extension or II.root if system indicates OID or GUID (Or Role.id.extension or root) | |
period | Role.effectiveTime or implied by context | |
assigner | II.assigningAuthorityName but note that this is an improper use by the definition of the field. Also Role.scoper | |
udi | .id and .code | |
id | n/a | |
extension | n/a | |
modifierExtension | N/A | |
deviceIdentifier | Role.id.extension | |
name | .displayName | |
jurisdiction | Role.scoper | |
carrierHRF | Role.id.extension | |
carrierAIDC | Role.id.extension | |
issuer | Role.id.root | |
entryType | NA | |
status | .statusCode | |
type | .code | |
id | n/a | |
extension | n/a | |
coding | union(., ./translation) | |
id | n/a | |
extension | n/a | |
system | ./codeSystem | |
version | ./codeSystemVersion | |
code | ./code | |
display | CV.displayName | |
userSelected | CD.codingRationale | |
text | ./originalText[mediaType/code="text/plain"]/data | |
lotNumber | .lotNumberText | |
manufacturer | .playedRole[typeCode=MANU].scoper.name | |
manufactureDate | .existenceTime.low | |
expirationDate | .expirationTime | |
model | .playedRole[typeCode=MANU].code | |
version | .softwareName (included as part) | |
patient | .playedRole[typeCode=USED].scoper.playedRole[typeCode=PAT] | |
owner | .playedRole[typeCode=OWN].scoper | |
contact | .scopedRole[typeCode=CON].player | |
location | .playedRole[typeCode=LOCE].scoper | |
url | .telecom | |
note | .text | |
id | n/a | |
extension | n/a | |
author[x] | Act.participant[typeCode=AUT].role | |
time | Act.effectiveTime | |
text | Act.text | |
safety | NA |
Zib VisualFunction VisualAid Product | ||
Device | administrative.device | |
identifier | id | |
identifier (serialNumber) | id | |
udi | id | |
deviceIdentifier | what | |
name | what | |
status | status | |
type | what | |
lotNumber | what | |
manufacturer | what | |
manufactureDate | what | |
expirationDate | what | |
model | what | |
version | what | |
patient | who.focus | |
owner | who.source | |
contact | who.source | |
location | where | |
url | where |
Zib VisualFunction VisualAid Product | ||
Device | ||
identifier | The serial number which is a component of the production identifier (PI), a conditional, variable portion of a UDI. The identifier.type code should be set to “SNO”(Serial Number) and the system left empty. | |
identifier (serialNumber) | The serial number which is a component of the production identifier (PI), a conditional, variable portion of a UDI. The identifier.type code should be set to “SNO”(Serial Number) and the system left empty. | |
udi | ||
deviceIdentifier | The device identifier (DI), a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. | |
name | Propietary/Trade Name of the medical Device as used in the labeling or catalog | |
carrierHRF | A unique device identifier (UDI) on a device label in plain text | |
carrierAIDC | A unique device identifier (UDI) on a device label a form that uses automatic identification and data capture (AIDC) technology. | |
issuer | All UDIs are to be issued under a system operated by an Jurisdiction-accredited issuing agency. GS1 DIs: http://hl7.org/fhir/NamingSystem/gs1 HIBCC DIs: http://hl7.org/fhir/NamingSystem/hibcc ICCBBA DIs for blood containers: http://hl7.org/fhir/NamingSystem/iccbba-blood ICCBA DIs for other devices: http://hl7.org/fhir/NamingSystem/iccbba-other | |
type | Type description using GMDN or other code system | |
lotNumber | The lot or batch number within which a device was manufactured - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. | |
manufacturer | N/A | |
manufactureDate | The date a specific device was manufactured - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. For FHIR, The datetime syntax must converted to YYYY-MM-DD[THH:MM:SS]. If hour is present, the minutes and seconds should both be set to “00”. | |
expirationDate | the expiration date of a specific device - which is a component of the production identifier (PI), a conditional, variable portion of a UDI. For FHIR, The datetime syntax must converted to YYYY-MM-DD[THH:MM:SS]. If hour is present, the minutes and seconds should both be set to “00”. |