Nictiz FHIR NL STU3 Zib2017
1.3.15 - CI Build

Nictiz FHIR NL STU3 Zib2017 - Local Development build (v1.3.15) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: SondeTypeCodelijst

Official URL: http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 Version: 1.3.15
Active as of 2024-04-09 Computable Name: SondeTypeCodelijst
Other Identifiers: http://art-decor.org/ns/oids/vs#2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1 (use: official)

Copyright/Legal: This artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/getsnomed-ct or info@snomed.org.

SondeTypeCodelijst

References

Logical Definition (CLD)

This value set includes codes based on the following rules:

  • Include these codes as defined in http://snomed.info/sct
    CodeDisplaySynonymNederlands (Nederland) (Dutch (Netherlands), nl)
    126065006Jejunostomy tubeJejunostomie katheterJejunostomie katheter
    470571004Gastrostomy tubeGastrostomie katheterGastrostomie katheter
    281414004Percutaneous endoscopic gastrostomy catheterPEG sondePEG sonde
    8921000146109Percutaneous radiological gastrostomy catheterPRG sondePRG sonde
    8851000146109Percutaneous endoscopic gastrojejunostomy catheterPEG-J sondePEG-J sonde
    8911000146104Percutaneous endoscopic jejunostomy catheterPEJ sondePEJ sonde
    17102003Nasogastric tubeNeus-maagsondeNeus-maagsonde
    8581000146101Nasojejunal tubeNeus-jejunumsondeNeus-jejunumsonde
    8591000146104Nasoduodenal tubeNeus-duodenumsondeNeus-duodenumsonde
  • Include these codes as defined in http://hl7.org/fhir/v3/NullFlavor
    CodeDisplayDefinitionSynonymNederlands (Nederland) (Dutch (Netherlands), nl)
    OTH Other Description:The actual value is not a member of the set of permitted data values in the constrained value domain of a variable. (e.g., concept not provided by required code system).
    Usage Notes: This flavor and its specializations are most commonly used with the CD datatype and its flavors. However, it may apply to *any* datatype where the constraints of the type are tighter than can be conveyed. For example, a PQ that is for a true measured amount whose units are not supported in UCUM, a need to convey a REAL when the type has been constrained to INT, etc.
    With coded datatypes, this null flavor may only be used if the vocabulary binding has a coding strength of CNE. By definition, all local codes and original text are part of the value set if the coding strength is CWE.
    Anders Anders

 

Expansion

Expansion based on:

This value set contains 5 concepts.

CodeSystemDisplayInactiveDefinition
  126065006http://snomed.info/sctJejunostomy tube
  470571004http://snomed.info/sctGastrostomy tube
  281414004http://snomed.info/sctPercutaneous endoscopic gastrostomy catheterinactive
  17102003http://snomed.info/sctNasogastric tube
  OTHhttp://hl7.org/fhir/v3/NullFlavorOther

Description:The actual value is not a member of the set of permitted data values in the constrained value domain of a variable. (e.g., concept not provided by required code system).

                       Usage Notes: This flavor and its specializations are most commonly used with the CD datatype and its flavors.  However, it may apply to *any* datatype where the constraints of the type are tighter than can be conveyed.  For example, a PQ that is for a true measured amount whose units are not supported in UCUM, a need to convey a REAL when the type has been constrained to INT, etc.

                    With coded datatypes, this null flavor may only be used if the vocabulary binding has a coding strength of CNE.  By definition, all local codes and original text are part of the value set if the coding strength is CWE.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code