Nictiz FHIR NL STU3 Zib2017
1.3.15 - CI Build
Nictiz FHIR NL STU3 Zib2017 - Local Development build (v1.3.15) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Official URL: http://nictiz.nl/fhir/StructureDefinition/zib-FeedingTubeSystem-Product | Version: 1.3.15 | |||
Active as of 2024-04-09 | Computable Name: Zib FeedingTubeSystem Product | |||
Copyright/Legal: CC0 |
This resource is part of FeedingTubeSystem as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) version 3.2, release 2017.
The purpose of a feeding tube is usually to administer food and/or medication. Information on present feeding tubes is recorded to inform other health professionals. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Zib MedicalDevice Product
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Zib MedicalDevice Product | Product | |
![]() ![]() ![]() |
0..1 | CodeableConcept | ProductType Binding: SondeTypeCodelijst (extensible): The code of the type of feeding tube product. | |
![]() |
Path | Conformance | ValueSet | URI |
Device.type | extensible | SondeTypeCodelijsthttp://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 from this IG |
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Zib MedicalDevice Product | Product | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
0..* | Identifier | ProductID Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
0..1 | Identifier | serial number (21) part of the UDI | |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. |
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/identifier-type |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() ![]() |
0..1 | CodeableConcept | ProductType Binding: SondeTypeCodelijst (extensible): The code of the type of feeding tube product. | |
![]() |
Path | Conformance | ValueSet | URI |
Device.identifier:serialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use from the FHIR Standard | |
Device.identifier:serialNumber.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status from the FHIR Standard | |
Device.type | extensible | SondeTypeCodelijsthttp://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-1 | error | Device | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() |
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | Zib MedicalDevice Product | Product | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: Common Languages (extensible): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
0..* | Identifier | ProductID Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() ![]() |
0..1 | Identifier | serial number (21) part of the UDI | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/identifier-type | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
Σ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | application identifier (AI) (01) part of the udi | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Device Name as appears on UDI label | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | ProductID | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | ProductType Binding: SondeTypeCodelijst (extensible): The code of the type of feeding tube product. | |||||
![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() |
0..1 | string | batch or lot number (10) part of the UDI | |||||
![]() ![]() ![]() |
0..1 | string | Name of device manufacturer | |||||
![]() ![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||
![]() ![]() ![]() |
0..1 | dateTime | expiration date (17) part of the UDI | |||||
![]() ![]() ![]() |
0..1 | string | Model id assigned by the manufacturer | |||||
![]() ![]() ![]() |
0..1 | string | Version number (i.e. software) | |||||
![]() ![]() ![]() |
0..1 | Reference(nl-core-patient) | Patient to whom Device is affixed | |||||
![]() ![]() ![]() |
0..1 | Reference(nl-core-organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | Reference(nl-core-location) | Where the resource is found | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Individual responsible for the annotation | |||||
![]() ![]() ![]() ![]() ![]() |
Reference(Practitioner | Patient | RelatedPerson) | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | dateTime | When the annotation was made | ||||
![]() ![]() ![]() ![]() |
1..1 | string | ProductDescription | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: DeviceSafety (example): Codes used to identify medical devices safety characterics. These codes are derived in part from the United States Food and Drug Administration recommendations and are provided here as a suggestive example. | ||||
![]() |
Path | Conformance | ValueSet | URI | |||
Device.language | extensible | Common Languages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.identifier:serialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use from the FHIR Standard | ||||
Device.identifier:serialNumber.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.udi.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status from the FHIR Standard | ||||
Device.type | extensible | SondeTypeCodelijsthttp://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 from this IG | ||||
Device.safety | example | DeviceSafetyhttp://hl7.org/fhir/ValueSet/device-safety from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-1 | error | Device | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() | (children().count() > id.count()) |
This structure is derived from Zib MedicalDevice Product
Differential View
This structure is derived from Zib MedicalDevice Product
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Zib MedicalDevice Product | Product | |
![]() ![]() ![]() |
0..1 | CodeableConcept | ProductType Binding: SondeTypeCodelijst (extensible): The code of the type of feeding tube product. | |
![]() |
Path | Conformance | ValueSet | URI |
Device.type | extensible | SondeTypeCodelijsthttp://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Zib MedicalDevice Product | Product | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
0..* | Identifier | ProductID Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
0..1 | Identifier | serial number (21) part of the UDI | |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. |
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/identifier-type |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() ![]() |
0..1 | CodeableConcept | ProductType Binding: SondeTypeCodelijst (extensible): The code of the type of feeding tube product. | |
![]() |
Path | Conformance | ValueSet | URI |
Device.identifier:serialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use from the FHIR Standard | |
Device.identifier:serialNumber.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status from the FHIR Standard | |
Device.type | extensible | SondeTypeCodelijsthttp://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-1 | error | Device | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | Zib MedicalDevice Product | Product | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: Common Languages (extensible): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
0..* | Identifier | ProductID Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() ![]() |
0..1 | Identifier | serial number (21) part of the UDI | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/identifier-type | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
Σ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | application identifier (AI) (01) part of the udi | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Device Name as appears on UDI label | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | ProductID | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | ProductType Binding: SondeTypeCodelijst (extensible): The code of the type of feeding tube product. | |||||
![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() |
0..1 | string | batch or lot number (10) part of the UDI | |||||
![]() ![]() ![]() |
0..1 | string | Name of device manufacturer | |||||
![]() ![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||
![]() ![]() ![]() |
0..1 | dateTime | expiration date (17) part of the UDI | |||||
![]() ![]() ![]() |
0..1 | string | Model id assigned by the manufacturer | |||||
![]() ![]() ![]() |
0..1 | string | Version number (i.e. software) | |||||
![]() ![]() ![]() |
0..1 | Reference(nl-core-patient) | Patient to whom Device is affixed | |||||
![]() ![]() ![]() |
0..1 | Reference(nl-core-organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | Reference(nl-core-location) | Where the resource is found | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() ![]() |
0..1 | string | xml:id (or equivalent in JSON) | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Individual responsible for the annotation | |||||
![]() ![]() ![]() ![]() ![]() |
Reference(Practitioner | Patient | RelatedPerson) | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | dateTime | When the annotation was made | ||||
![]() ![]() ![]() ![]() |
1..1 | string | ProductDescription | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: DeviceSafety (example): Codes used to identify medical devices safety characterics. These codes are derived in part from the United States Food and Drug Administration recommendations and are provided here as a suggestive example. | ||||
![]() |
Path | Conformance | ValueSet | URI | |||
Device.language | extensible | Common Languages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.identifier:serialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use from the FHIR Standard | ||||
Device.identifier:serialNumber.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.udi.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status from the FHIR Standard | ||||
Device.type | extensible | SondeTypeCodelijsthttp://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1--20171231000000 from this IG | ||||
Device.safety | example | DeviceSafetyhttp://hl7.org/fhir/ValueSet/device-safety from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-1 | error | Device | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() | (children().count() > id.count()) |
This structure is derived from Zib MedicalDevice Product
Other representations of profile: CSV, Excel, Schematron