Publications of the World Health Organization enjoy copyright protection in accordance with the provisions of Protocol 2 of the Universal Copyright Convention. All rights reserved.
The UCUM codes, UCUM table (regardless of format), and UCUM Specification are copyright 1999-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. https://ucum.org/trac/wiki/TermsOfUse
This material contains content that is copyright of SNOMED International. Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact https://www.snomed.org/get-snomed
or info@snomed.org
.
Copyright/Legal: This artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/getsnomed-ct or info@snomed.org. ( src
)
Nictiz FHIR NL STU3 Zib2017 - Local Development build (v1.3.15) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions ( src
)
There are examples where a medication request may include the option of an oral dose or an Intravenous or Intramuscular dose. For example, "Ondansetron 8mg orally or IV twice a day as needed for nausea" or "Compazine® (prochlorperazine) 5-10mg PO or 25mg PR bid prn nausea or vomiting". In these cases, two medication requests would be created that could be grouped together. The decision on which dose and route of administration to use is based on the patient's condition at the time the dose is needed. ( src
)
StructureDefinition for DocumentManifest as represented in the Provide and Query interactions in the
IHE IT Infrastructure Technical Framework Supplement Mobile access to Health Documents (MHD) Rev. 2.3
.
The IHE MHD Profile text is Normative, this conformance resource is Informative.
StructureDefinition for List Resource supporting XDS Folders in the
IHE IT Infrastructure Technical Framework Supplement Mobile access to Health Documents (MHD) Rev. 2.3
.
The IHE MHD Profile text is Normative, this conformance resource is Informative.
StructureDefinition for DocumentRefererence as represented in the Provide Document Bundle (ITI-65) transaction with Minimal Metadata compliance in the
IHE IT Infrastructure Technical Framework Supplement Mobile access to Health Documents (MHD) Rev. 2.3
.
The IHE MHD Profile text is Normative, this conformance resource is Informative.
StructureDefinition for Provide Document Bundle (ITI-65) transaction between the MHD Document Source and the MHD Document Recipient with Minimal metadata compliance in the
IHE IT Infrastructure Technical Framework Supplement Mobile access to Health Documents (MHD) Rev. 2.3
.
The IHE MHD Profile text is Normative, this conformance resource is Informative.
Important: this ValueSet has been copied from IHE. It is published by Nictiz through the IHE domain as to guarantee continuity and availability of this profile. The IHE FormatCode Value set is defined to be the set of FormatCode(s) defined by IHE
.
This ValueSet additionally includes format codes defined by the HL7 CDA
.
The set was listed in HITSP C80 Table 2-153 Format Code Value Set Definition.
The use of the FormatCode specifies the technical format of the document.
The FormatCode is a further specialization more detailed than the mime-type.
The FormatCode provides sufficient information to allow any potential document consumer to know if it can processing/display by identifying a document encoding, structure and template.
The actual list of codes is intended to be extensible.
In FHIR STU3 and R4, the Period datatype has an invariant that inconsistently in text states that Period.start
shall be lower than Period.end
, but actually supports lower than or equal to
in its expression, which reflects the original intent. This has been fixed for FHIR R5 so the text now reflects the expression. This means that, for GP systems that only have a date, both Period.start
and Period.end
should be populated with the same date. See MM-1453
and FHIR-28621
that discuss this issue.
Also note that there is the additional profile zib-LaboratoryTestResult-DiagnosticReport
, which is used for (textual) reports on individual (panels of) observations, like conclusions. The DiagnosticReport contains references to instances of this profile and can be used in all three the situations described above.
Known issue: this profile does not constrain the units allowed in .valueQuantity
. When exchanging data based on NHG Table 45
, it is expected that .code
equals 'mmol/L'. See <https://bits.nictiz.nl/browse/MM-2607> for more details.
The HCIM LaboratoryTestResult supports simple and more complex situations. This profile is used for (textual) reports on individual (panels of) observations, like conclusions. The actual tests are captured using the profile zib-LaboratoryTestResult-Observation
, which should be referenced from this resource.
Known issue: this ValueSet contains system value ‘urn:oid:2.16.840.1.113883.6.90’, while according to https://www.hl7.org/fhir/stu3/icd.html
uri ‘http://hl7.org/fhir/sid/icd-10-cm’ is expected. This cannot be edited due to backwards compatibility of this ValueSet. See https://bits.nictiz.nl/browse/MM-2801
for more details.